By Application · 03

Sewage Pumps & Knife Gates for Wastewater Stations

Sewage pumps, flood pumps, knife gates and channel sluice gates for wastewater and stormwater stations. This page sorts the range by what the station has to do: lift sewage out of a wet well, prime from a sump with no pump house, move stormwater at low head, cut off a channel, or stop backflow at a pump. Sizes, heads and materials are read from the product data, and each card opens the full parameter tables for its lead model.

All 56 SKUs for this application

Materials & standards

What each series is cast or lined in, and the standards and data its dimensions come from.

Submersible & Non-Clog Sewage Pumps

Read from Submersible Sewage Pump (WQ / QW) — WQ / QW · DN25–600

Wetted PartsCast iron as standard; stainless steel for lightly corrosive media
ImpellerSingle or double vane non-clog design
Shaft SealDouble mechanical seal in a separate oil chamber, water-sensing probe fitted
MotorSubmersible, thermal element in the stator, IP68 cable entry
BodyCast iron HT200 / ductile iron QT450

Series ranges are for preliminary selection; the final model is selected against the duty point and the printed curve.

Self-Priming Sewage Pumps

Read from Self-Priming Sewage Pump (ZW / ZWL) — ZW / ZWL · 51 models · DN25–DN300

BodyCast iron HT200 / ductile iron QT450
Stormwater & Flood Axial Pumps

Read from Submersible Axial-Flow / Mixed-Flow Pump — DN350–DN1600 · up to ~30,000 m³/h

BodyCast iron / ductile iron
Knife Gates & Channel Sluice Gates

Read from General Knife Gate Valve — GPZ73 · DN25–DN1200

BodyCarbon steel / stainless steel / duplex steel / special material
GatePrecision-machined knife gate with a cutting edge
SeatIndependent replaceable seat — metal (hard) or resilient (soft)
Stem SealingMoulded packing, upper seal
Body ConstructionCompact one-piece body, no solids pocket

Standards / data basis: MSS SP-81 · MSS SP-81 (design and face-to-face)

Check Valves at the Pump Station

Read from Swing Check Valve (DIN F6) — DIN F6-H44T · DN50 – DN400

BodyDuctile iron, epoxy coated; duplex 2205 / 2507 available on request
DiscBrass-welded or EPDM-faced swing disc
Guide Shaft304 stainless steel
TrimStainless steel (grade per order)

What we need to quote

A pump or a lined valve is quoted against the duty point, not off a catalogue page. Send these and the reply is a model with its curve, not a range.

  1. 01Flow (m³/h) and head (m) — for stormwater, the design rainfall flow the station must pass
  2. 02Solids handling — the free passage the pump needs, and whether the flow is fibrous
  3. 03Installation — wet well, dry pit, sump without a pump house, or an open channel
  4. 04Line or channel size, and the medium temperature (these pump builds are rated to 40 °C)